Carro de la compra

No hay artículos en el carro

No hay artículos en el carro

Little Giant VCMA-15ULS 554405 VCMA Series Bomba de eliminación automática de condensado, 1/30-HP, Tala Única, N/A

Envío gratis en pedidos superiores a Mex $600.00

Mex $1,642.04

Mex $ 689 .00 Mex $689.00

En stock

1.Nombredelestilo:Grafito/negro


Acerca de este artículo

  • Bomba de condensado automática: cuenta con un interruptor de tipo vertical para reducir la huella y está diseñado para quitar automáticamente el condensado producido por calderas, hornos, acondicionadores de aire y deshumidificadores
  • Motor de alto rendimiento: 1/30 CV, 1.5 amperios, 93 vatios, 115 voltios, 60 Hz, motor térmico protegido, refrigerado por ventilador; CSA listado en los Estados Unidos y Canadá
  • Construido para durar: eje del motor de acero inoxidable, motor protegido contra sobrecarga térmica; certificado CSA según las normas estadounidenses y canadienses
  • Bomba con interruptor de seguridad: se puede conectar para apagar el condensador de aire acondicionado o cablear a una alarma para advertir del posible desbordamiento del tanque
  • Especificaciones: descarga de púas de 3/8 pulgadas de diámetro exterior, 80 GPH a 1 pie de cabeza, 20 pies de apagado, hasta 8.7 PSI, 3 agujeros de drenaje de entrada, cable de 6 pies; temperatura máxima del agua: 140 F, equipado con interruptor de seguridad



Más información del producto

little giant

damose
Comentado en los Estados Unidos el 6 de marzo de 2025
Easy to install. This was a replacement for another one just like it that lasted for more than 10 years. Setup took just a couple minutes and it worked instantly. Very reliable. Don't forget to clean out sludge from the HVAC unit now and then. Great product.
Kitchen Panda
Comentado en Canadá el 13 de marzo de 2025
On a cold November morning we discovered our furnace had quit - subsequently discovered that it needed so much in repairs, it made sense to replace. Our furnace contractor was quite happy for us to supply our own condensate pump since it was less costly than what they would have to charge us. The only drawback in this pump is that it seems much noisier than our old Little Giant, which could not be heard outside of the furnace room - this one makes a shrill sound that carries up the stairs. But it made it through the winter with no issues. It even came with a new check valve.
Shannon
Comentado en Canadá el 18 de julio de 2024
After my furnace condensate pump failed I tried getting a replacement locally, but the nearby hardware stores either didn't have any in stock or the price was more than double.This one was a fair price, arrived the next day, and has worked flawlessly since I installed it.
Share-rating
Comentado en Canadá el 23 de septiembre de 2024
This pump will replace the identical unit that I use for our air conditioner. It is reliable and works well. Delivery was quick. Turns out my assumption that the old unit was broken was incorrect. I hadn't cleaned it after 9 years of use and it was loaded with sludge preventing the float from working properly. A good cleaning brought it back to life so the old unit is still in service. I decided the new unit will serve as backup in the event the old pump fails.
FELIPE
Comentado en México el 11 de abril de 2024
Buen producto, empaque solo un poco maltratado.
Ellen
Comentado en los Estados Unidos el 20 de noviembre de 2020
First, the crap and gunk that this unit battled - I am amazed that it was still running. Here are some notes from my experience:-+ DON'T ASSUME THE PUMP TANK IS CLEANED WITH ANNUAL OR PERIODIC SERVICES. Many companies (I have experience with a fairly wide range) will do just enough to clear the lines and keep the unit functioning. Not once have any of the companies *ever* cleaned this tank.+ DON'T ASSUME THE PUMP IS REPLACED WHEN THE FURNACE IS REPLACED. We had a huge, new Lennox system installed and the not inexpensive, certified installers just left the old pump in place. If the photo wasn't so terrible, I'd attach it. Cannot believe this Little Giant battled through.+ DRAIN LINE. There was so much gunk in the unit that the line out was also full of sediments. I replaced it based on guidance from amazon contributors. It was not at all difficult. I think you will do much more for your own unit than someone normally has time to do on a usual service. If you want it replaced, it is probably something you'd have to specially request.+ DRAIN LINE CONFIGURATION. There are notes on how to do this given your specific location (rise precedes horizontal run, length, etc.). Mine was twisted, tied so tightly to the pipes that it was constricted in multiple places, and the run configuration was inverted. The Little Giant manual contains relevant info. as well.+ REPLACEMENT. For less than $50 it is much, much more economical to replace the pump. There are also many good notes in the reviews -- together with You Tube vids.+ INTAKE PIPES. I just knew before I removed the unit, I'd find that the ends of the pipes were not only flat cut, but also almost flush up against the bottom of the tank. A read of the very straightforward installation instructions highlights this as an issue. It's just not something the normal retail customer would even know to check until a water or functional issue develops. Cut at a 45 degree angle.+ P TRAP. So important and so often overlooked. Equipment manufacturers may not really focus on these, and service technicians are busy once there's an obvious fail. My installation was riddled with errors. No wonder it has been leaking for years. Every time I asked about it, every co. agent just said, yeah, they do that. Well they do if they are not installed correctly. It is easy to check the levels and venting requirements by reading 1.5 pages of the manual. Risks of improper installation: water damage to the system and area, and worse, distribution of substandard air throughout the house.+ MAINTENANCE. The tank needs to be flushed and cleaned regularly. That's IMPORTANT. From what I gleaned, that's a minimum of every 2 years........ but realistically at *least* annually (with that service contract) and possibly more frequently in humid or damp areas.I have friends who are GREAT service technicians. I admire their skills. The thing is that unless you understand the equipment in your own house, it's hard to appreciate those talents -- and also know when someone is lacking. It also helps to do some normal maintenance to preclude issues.Edit: The check valve (and float switch) supplied with the unit are working well; no issue and there is a 10 ft vertical run preceding the inverted U down to the drain entry point. Nevertheless I will cut in a second check valve given the length of the vertical rise.
Productos recomendados

Mex $3,027.78

Mex $ 1,362 .00 Mex $1,362.00

4.6
Elegir